Proxycon Network Locks

What is it

The Blue Touch is a completely new modern access control system in the rooms by activating electric door tabs, consumption control room and independent climate control.

Λήψη ιστορικού προσβάσεων δωματίου

Κατασκευή κάρτας προσωπικού

How it Works

The technique uses RF-ID technology based RF-ID, widespread technology systems immobilizer keys of the car. The system uses a special chip mounted on the card – key, which exchanges data with sockets control room every time she is in the range of the signal emitted outlet.

The microchip of the card draws power for the operation of the emitted signal from the plug (not any use batteries). The transmission range extends just 5 cm from the outlet is low, non-harmful frequency (125 khz), thus requiring almost touching the card to it. This method surpasses any problems contact, humidity, outdoor use, etc., which are other systems type smart card, magnetic card, etc. It is very reliable and for this reason widely used in industry, identification and control systems which require very high safety standards.

The system is local control, operated and programmed independently by the hotelier using Master Card, without requiring use or interface with PC. Programming is done once initially, during installation and then only if a card is lost and require replacement. The lights led the internal socket guide the hotelier by the simple process of scheduling.

The system also provides Blue Touch central door opening and access or ban on prepaid or free service as parking, gym, function or not, air conditioning etc. The module table ProxyCon, even includes two relay loads, each contact 16A (resistive load) to manage the load of lights and air conditioning. Even has a relay contact 1A for electrical stimulation of tongue door, with a choice of output 12V dc / 500ma or cold contact to use an external power supply.

For feeding the uses powerful Switching power supply capable of operating at high or very high blood pressure dipping (PPC mode voltages from 80 to 250 Volt). Also has a serial input for possible upgrade of the operating program of the microcontroller.

It offers a variety of functions while maintaining a very affordable price, ideal for use in apartments and small hotels.

Advandages

  • Silent door opening
    • By tapping the card on the outer wall of the room to activate the electric door mechanism for 4 seconds, the indicator lights Door opener and the lights of the room for 1 minute. The system controller supplies the electrical mechanism of the door with a voltage so as not to create any noise.
  • Checking consumption
    • By placing the card in slot illuminated internal socket, lights and air conditioning remain activated for as long as the controller of the system ‘reads’ the card. By removing the card from the socket lights and air conditioner off after 1 minute.
  • Independent control of air-condition
    • In an occupied room, the system allows the air conditioner only if the balcony door closed. Allows operation of air conditioning balcony door open for 3 minutes, time enough for the client to ventilate the room or visit the verandah. If the balcony door open for longer, then the air conditioner turned off until the balcony door closed. The right to use conditioning information is written on the card, allowing the sale of air conditioning, as extra service, using a second set of cards ‘NO AIR-CONDITION’.
  • Multiple users per room
    • The system recognizes and allows access to 3 different card customers per room and 2 different groups-categories card pass partout (eg cleaners, maintenance workers). We can give more than one card – key in suite ‘the families hosted in your apartments.
  • Do Not Disturb
  • The occupant of the room if occupied, can be enabled as ‘not bothered’ by pressing the corresponding button of the internal socket room. Thus prohibiting the entrance of the room maid. (For safety reasons do not disturb mode can be canceled by the hotel’s master key chains).
  • Room Status Indicator
    • All functions and the condition of the room depicted in lights led the external (and internal) outlet in the room.
    • Turn-door: green LED Door opener / Alarm for 10 seconds.
    • -Room occupied: green LED Room occupied.
    • -Do Not Disturb: red light Do not disturb.
    • Open balcony-free in room: fast blinking LED Door opener / Alarm.
  • Night Lights
    • All sockets (internal and external) system lit blue touch the top of the intense but discreet blue light night to help tenants when the lights are off in the room or the corridors.
  • Access to main entrance, other inputs
    • Add module ProxyCon-2RD, planned as a central entrance, parking, entrance access 1 έως 5 etc can be used in various areas of the hotel. Moreover, it can be networked together with module ProxyCon-Net, in places that require registration and control of events in a computer (the cards and how their encoding is fully compatible with the system ProxyCon-Net and the program Talos-net).
  • Customer segments, prepaid services
    • Additional codes may be used according to the needs of each hotel even for presale services, access or otherwise of these reviews. For example, every time they planned or already in use smartcards with the right air conditioning, parking, access to gym etc as long as these services are charged extra. * (For the above function requires the central device Nemesis RF-ID programmer at the reception)

System Parts

  • BT-EXT: Outdoor wall illuminated blue touch, transceiver RF-ID code.
  • BT-INT: Internal illuminated wall blue touch, transceiver RF-ID code.
  • RF-ID CARD: Card RF-ID and four-color printing on 2 sides (user and logo of the hotel).
  • PROXyCON-2RD: controller socket management approach blue touch and relay management loads.
  • GEVI: Electric Kypri door.
  • OPTEX: Magnetic contact doors.
  • Optional
    • PSU 5-24: Variable power supply switching, 5 to 24Volt DC / 10Watt to open the electric door. Nemesis RF-ID programmer: Reader and programming services on cards RF-ID. (OPTIONAL) Sockets VR-EXT & VR-INT frames VIMAR (many colors available in plastic or chytopressarista)

Real Time Control (optional)

  • The Proxycon 2RD-RTC has also real-time controller (clock) powered by internal battery lasting 10 years, and internal memory log room with ability to capture the 3,000 past events (entry – exit of staff and tenants, list of banned cards list change data room, etc.).
  • It has a serial communication input, through which is the configuration of each room or other place (No Room, No building code, hotel, date – time, time delay switch off lights when leaving, delay-off air after opening doors, duration of electrical activation Kypri door etc).
  • This action is done only once, during installation of the systems by installers. For this purpose, each installation of Proxycon 2RD-RTC, available an adaptor, Serial to USB.
  • Thus, devices Proxycon 2RD-RTC, do not require local planning cards, but the programming card customers, staff, conservators, etc., is done centrally from Reception through a simple and intuitive program, TELETECHNIKA – CARD MANAGER and device programming card NEMESIS USB.
  • Also, through the serial port and is an upgrade the Firmware of the device Proxycon 2RD-RTC. The same port is used to download events from Cam Room Proxycon 2RD-RTC, if necessary (if stolen – enter the room any unauthorized person, etc.).

History Example

Personal Card Write

Share